Furnace blower motor replacement - About This Product. These motors install with all standard 48 in. Frame mounting brackets. They are a quiet operator and electrically reversible. There is an automatic thermal overload protector and they have class B insulation. The speed is 1075/3 and 60 Hz with low power consumption. The motor uses a 370-Volt Capacitor and has a standard 48 ...

 
8 Apr 2015 ... How to replace and install 60L21 blower motor on a Lennox G40 LP furnace. We also show you how to remove and replace the blower wheel and .... Bacon egg and cheese bagel near me

The blower motor on our oil furnace started making awful noises and refusing to work. I've replaced it before but used a "budget" motor. It lasted 10 years. ...HQ1012514EM – Heil OEM Furnace Blower Motor. When it comes to reliability, the HQ1012514EM Heil OEM Furnace Blower Motor stands out as a dependable replacement option for Heil furnace systems. With a voltage of 115 volts and a horsepower of 0.33 HP, this motor is built to deliver optimal performance.To purchase a new furnace blower motor, you’ll need to examine the faceplate on your old furnace blower motor for a model number. This model number can be used to match up to your replacement. Though, if you cannot find an exact model number replacement, a universal replacement blower motor that has the same HP, …Instructions for Replacement Furnace Blower Motors. By Amy Rodriguez Updated April 18, 2012 9:47 a.m. ... Over time, the furnace blower motor can become internally worn from age and lack of lubrication, causing a major reduction in warm air movement through the home's ductwork.Nov 30, 2023 · The average cost to replace a broken furnace or air handler blower motor is around $290 when the part is under warranty and you pay just the labor cost. When the blower motor is not under warranty, the average cost is around $890 which includes parts and labor for a standard HVAC blower motor. The installed replacement cost should include a ... Instructions for Replacement Furnace Blower Motors. By Amy Rodriguez Updated April 18, 2012 9:47 a.m. ... Over time, the furnace blower motor can become internally worn from age and lack of lubrication, causing a major reduction in warm air movement through the home's ductwork.Since my search for the same replacement brought me here, I'll share my experience if it helps anyone in the future. The motor itself, I couldn't find anywhere either. The entire blower (80594) direct from US Stove is $349, so that was a bit of a turn off. Fleet Farm has it for $240 and Rural King has it for $200.The blower motor on our oil furnace started making awful noises and refusing to work. I've replaced it before but used a "budget" motor. It lasted 10 years. ...Carrier HC41AE117 Furnace Blower Motor . $438.24. Compare. Choose Options. Carrier HC45AE118 Blower Motor , GE model 5KCP39PGS171S . $649.24. Compare. ... Evergreen VS Blower Motor 1/2hp Replacement for Genteq ECM 2.3, Eon & 3.0 motors. $659.99. Add To Cart. Lennox 60L22 1/2 hp blower motor canada. $489.22.Oct 13, 2023 · Most residential furnace blower motors cost between $120 and $1,000, with the nationwide average being $550 for a blower motor replacement. However, high-end furnace blowers for extra-large units or furnaces that are difficult to access can cost significantly more at $2,000 or more. Blower Motor Replacement vs Furnace Replacement. Here are issues to think through as you consider your choice. In short, if the furnace is less than 12 years old and has served you well, plus you’ve kept up with …A blower motor is part of the heating and cooling system in a house or other building. It pushes heated or cooled air through the ductwork of the building. Blower motors are also u... Furnace/AC blower motor replacement or how to replace your furnace blower motor. We smelled a burnt plastic smell in the house and my wife mentioned that the... Oct 15, 2013 · This item: 60L22 - Lennox OEM Replacement Furnace Blower Motor 1/2 HP 115 Volt . $245.00 $ 245. 00. Get it Mar 19 - 21. Only 10 left in stock - order soon. Dec 12, 2023 · Step-By-Step Guide For Blower Motor Replacement. To replace a furnace blower motor, follow these step-by-step instructions: Step 1: Begin by turning off the power supply to the furnace for safety. Step 2: Remove the panels surrounding the furnace to access the blower assembly. Top 10 Best Furnace Blower Motor Replacement in San Diego, CA - February 2024 - Yelp - Prime Air Solutions, Home Dr, Big City AC Heating & Appliance Repair, FREON Service, Air Conditioning and Heating - San Diego, San Diego Air Conditioning & Heating, Prothermal, Rg Heating & Cooling, Ms. Cool MrCool Sales, Consultation and Installation, SpeedMates Home Services Furnace/AC blower motor replacement or how to replace your furnace blower motor. We smelled a burnt plastic smell in the house and my wife mentioned that …Our furnace blower motor replacements and parts are affordable and come with fast shipping. Buy quality OEM inducer blower motors today. En español. 1-800-269-2609 ... related items are needed for replacement motor. ADD TO CART. Furnace Draft Inducer Motor. Genuine OEM Part # 347822-763 | RC Item # 4978924. 5 star rating. Reviews. …York furnace motors Canada. York inducer motors, exhaust blower motor whole assembly. York AC fan motors and fan blades Furnace Motors Canada Tel: 647-793-4999 ... Search. CONTACT; Home; Catalog; Blog; HELP VIDEO; Shipping/Returns; Covid19 shipping impact; FIND your replacement motor CONTACT US 647-793-4999; SAME …The blower motor in the HVAC starts, then stops an excessively large furnace for the house. HVAC blower motor duct design is inadequate. The furnace blower fan should start on 1.5 to 3 minutes after the thermostat signals a need for heat and should go off several minutes after the heating cycle is complete under typical circumstances.About This Product. These motors install with all standard 48 in. Frame mounting brackets. They are a quiet operator and electrically reversible. There is an automatic thermal overload protector and they have class B insulation. The speed is 1075/3 and 60 Hz with low power consumption. The motor uses a 370-Volt Capacitor and has a standard 48 ...The EC Max is designed as the ideal direct-drive blower motor to replace hundreds of existing motor types and brands, providing exceptional efficiency and performance to meet strict energy efficiency regulations. This outstanding motor offers over 80% energy efficiency, compatibility with both 120V or 230V power supply, and simple … A malfunctioning blower motor is the number one cause of a furnace not circulating heated air through the home. If you’ve determined the motor is receiving power, check to see if the blower wheel rotates freely. If it doesn’t, it’s likely the motor bearings are locked up and the motor will need to be replaced. The HC45AE118 furnace fan blower motor is used in over 540 Bryant Carrier furnaces. The HC45AE118 Bryant Carrier furnace blower motor replacement has HC45AE118A on the motor label, but has HC45AE118 on the OEM factory authorized parts box that the motor comes in. This motor replaces old part number HC45AE117.Furnace/AC blower motor replacement or how to replace your furnace blower motor. We smelled a burnt plastic smell in the house and my wife mentioned that …A gas furnace uses a negligible amount of electricity for lighting the flame. The major amount of electricity used with gas heating is in connection with the blower, and the watts ...Furnace/AC blower motor replacement or how to replace your furnace blower motor. We smelled a burnt plastic smell in the house and my wife mentioned that …Find our videos and blogs here: https://www.repairclinic.com/Content-Library Main site here: https://www.repairclinic.com/This video provides general informa...Oct 15, 2013 · This item: 0131F00022 - Goodman OEM Replacement Furnace Blower Motor 1/2 HP 115 Volt . $140.45 $ 140. 45. In Stock. Ships from and sold by North America HVAC. + Furnace filters have an arrow that point to installation towards the evaporator coil, fan and blower motor located inside the air handler. If there are no arrows on the filter, ins...Furnace replacement costs $4,700 on average, but you might spend more or less depending on where you live, ... Blower motor: $150 - $450: Up to $2,000: Heat exchange: $100 - $200: Up to $1,500 ...2 Apr 2018 ... You should check the temp rise thru the furnace later to make sure it is not overheating as it may need a higher fan heat speed. Hookup the ...9 Jan 2017 ... 2 Answers 2 ... I would replace the motor with a 4 speed PSC motor. Psc motors have more starting torque than non PSC motors and use less ... Top 10 Best Furnace Blower Motor Replacement in San Diego, CA - February 2024 - Yelp - Prime Air Solutions, Home Dr, Big City AC Heating & Appliance Repair, FREON Service, Air Conditioning and Heating - San Diego, San Diego Air Conditioning & Heating, Prothermal, Rg Heating & Cooling, Ms. Cool MrCool Sales, Consultation and Installation, SpeedMates Home Services Leaf blowers are best used to clean up ... leaves. You should be cleaning your dryer vent about once a year, and while it can be a slightly inconvenient task, it’s important to kno...Check the Circuit Breaker: Start by checking the circuit breaker that powers your furnace. If the breaker has tripped, reset it and allow the system to go through a normal heating cycle. A tripped breaker can sometimes be the cause of a non-functioning blower motor. Inspect the Thermostat: Ensure that your thermostat is set correctly and ...The news from your HVAC repairman that you need a new furnace is definitely not a welcome experience. Use this guide to find the top reviewed Bryant furnaces when replacing your fu...If you have to work on a Suburban furnace you need to watch this video. Merchandise https://hillbilly-rv.creator-spring.com ...Oct 15, 2013 · This item: 0131F00022 - Goodman OEM Replacement Furnace Blower Motor 1/2 HP 115 Volt . $140.45 $ 140. 45. In Stock. Ships from and sold by North America HVAC. + K55HXKEB-9467 – Emerson OEM Furnace Blower Motor – 1/2 HP 115 Volt Product Description & Features: This is a Brand New OEM Furnace Replacement Blower Motor Top Qualty OEM Replacement Part! 1/2 HP 115 Volt Brand: OEM Replm for Emerson Manufacturer: Emerson *** Estimated Price: $302.00 + CLICK HERE for more …The cost of repair is often just as high as the cost of a new motor, so it makes sense to choose replacement when a furnace motor fails. The average life of a residential furnace blower motor is 15-20 years, and the cost of replacement can be as low as $150 up to $800 or more depending on the manufacturer and type of motor.The EC Max is designed as the ideal direct-drive blower motor to replace hundreds of existing motor types and brands, providing exceptional efficiency and performance to meet strict energy efficiency regulations. This outstanding motor offers over 80% energy efficiency, compatibility with both 120V or 230V power supply, and simple … Take out the motor. You will need to disconnect the connections first. Take the motor unit out. Remove the bolts. Take the motor out of the furnace. To take the motor out of the fan unit you will have to check all the screws that you need to take out. The motor has a bracket that will be there fitted with the motor. AS31XH280 - Carrier OEM Replacement Furnace Inducer Motor Blower Wheel Propeller 4.5 out of 5 stars 105. Quick look. $94.50 $ 94. 50. Replacement for Rheem Furnace Vent Venter Exhaust Draft Inducer Motor 70-24157-03 4.7 out of 5 stars 73. Quick look. $45.00 $ 45. 00. Pellethead ...Mar 23, 2010 · Step 2 - Locate the Furnace Fan and Motor Assembly. Turn off the furnace and disconnect it from any electrical sources. Lay your tarp or old blanket beside the furnace. Find the access panel for the furnace fan, covered by an access panel on the side of your furnace. Release the clips on the access panel and remove it from the furnace. Learn when to replace or repair your furnace blower motor based on the age, condition, and cost of the unit. Find out the average costs, benefits, …The HC45AE118 furnace fan blower motor is used in over 540 Bryant Carrier furnaces. The HC45AE118 Bryant Carrier furnace blower motor replacement has HC45AE118A on the motor label, but has HC45AE118 on the OEM factory authorized parts box that the motor comes in. This motor replaces old part number HC45AE117.Since my search for the same replacement brought me here, I'll share my experience if it helps anyone in the future. The motor itself, I couldn't find anywhere either. The entire blower (80594) direct from US Stove is $349, so that was a bit of a turn off. Fleet Farm has it for $240 and Rural King has it for $200.Blower Motor Replacement vs Furnace Replacement. Here are issues to think through as you consider your choice. In short, if the furnace is less than 12 years old and has served you well, plus you’ve kept up with …Buy it with. This item: B1340022 - Goodman OEM Replacement Furnace Blower Motor 3/4 HP. $23998. +. Upgraded Replacement fits Goodman Furnace Flame Sensor B11726-06. $428. +. Goodman / Amana Parts …Learn the steps to replace your furnace's circulation blower fan motor, a part of the heating or cooling system that draws air through the return vent and forces it …The first step in this process will be to determine if your furnace blower motor is dying or if it just needs lubrication. If it is dying, then the only fix is a replacement motor. If it just needs lubricating, you have several duties to perform. A lot of the time, the noises you hear come from the fan and not the motor.10 June 2023 ... My pleasure. You've done well, and well to reach out. On my end, it is heartwarming to help! Keep me posted, ... Read on to determine if your blower motor is malfunctioning and when to call a professional HVAC contractor to examine, repair or replace it. Indications of a Faulty Furnace Blower. The blower in a furnace is made up of a motor, fan blades in a cage (squirrel cage), and an electrical system to power it and control it. Any one or more of these ... 1.3K. 269K views 9 years ago. This video is about how to replace a broken or burned-out blower motor in your air conditioner/furnace HVAC unit. …How to replace a furnace blower motor. Maintenance Man. 834 subscribers. Subscribed. 961. Share. 91K views 2 years ago YMCA CAMP AT …Rheem Furnace Blower Motor Cost. Rheem furnace blower motor replacement costs around $250 to $1,000 – without labor. You might save some money replacing the motor by yourself. These are just a few of the …Century UST1102 1-Horsepower Up-Rated Round Flange Replacement Motor (Formerly A.O. Smith ... Consolidated Industries Furnace Draft Inducer Blower (JA1P082, 401570, JA1P103 ) AO ... 277 Volts0.78 Amps, 48 Frame, Sleeve Bearing Direct Drive Blower Motor Product Description & Features: 1/6 HP 1075 RPM 277 volts Brand: …K55HXKEB-9467 – Emerson OEM Furnace Blower Motor – 1/2 HP 115 Volt Product Description & Features: This is a Brand New OEM Furnace Replacement Blower Motor Top Qualty OEM Replacement Part! 1/2 HP 115 Volt Brand: OEM Replm for Emerson Manufacturer: Emerson *** Estimated Price: $302.00 + CLICK HERE for more …The price to replace a blower motor varies. For do-it-yourself repair for a small, single-speed motor, a furnace blower motor may cost you anything beyond $115.However, if you’re taking an experienced professional help and you’ve got a large furnace with a robust variable-speed blower motor, the cost of replacement can cross …The cost of repair is often just as high as the cost of a new motor, so it makes sense to choose replacement when a furnace motor fails. The average life of a residential furnace blower motor is 15-20 years, and the cost of replacement can be as low as $150 up to $800 or more depending on the manufacturer and type of motor.4 Apr 2022 ... Weak airflow means that the furnace blower motor has difficulty pushing air through the ducts to reach your desired temperature. The weak ...Furnace Blower Motor Cost. If your furnace is still under warranty, you may only have to pay around $150 for labor costs. But if your warranty has ended, Furnace Blower Motor Replacement Cost about $250 to $1000 without labor cost. You might spend up even more depends upon on the brand of your furnace. If you hire an HVAC technician, the ...Whether you need a York furnace model number or a Goodman furnace model number, it’s a good idea to know where to find furnace model numbers and how to decode them. These numbers a... Step By Step Instructions. Print Instructions. 1. Before you replace the blower motor in your furnace first turn off the power to the furnace. 2. Use a flat-head screwdriver to unthread the screws securing the upper access panel and remove the panel. 3. Next, unthread the screws to release the lower access panel. 4. Dec 12, 2023 · Step-By-Step Guide For Blower Motor Replacement. To replace a furnace blower motor, follow these step-by-step instructions: Step 1: Begin by turning off the power supply to the furnace for safety. Step 2: Remove the panels surrounding the furnace to access the blower assembly. Furnace Blower Motor Replacement Cost. A furnace blower motor replacement costs around $250 to $910 for parts and labor. The part costs an average of $100 to $500, and labor costs about $150 to $410.. The part alone can cost as high as $2,000, depending on the brand and size of the unit, with an HVAC technician taking approximately two to three …As a homeowner, one of the most important things you need to consider is the condition of your furnace. If you have an old or inefficient furnace that is no longer working properly... Carrier Blower Motor Replacementwww.amazon.com/shop/miheatingguyMilwaukee 2131-20 M18 ROCKET Dual Power Tower Lighthttps://amzn.to/3pe2hYHMilwaukee M12 Surge... Steve at HvacPartsShop.com provides comprehensive guidance on the topic of universal replacement blower motors for HVAC applications. Watch Steve explain the...Replacement begins with shutting off power to the furnace, removing the access panels and then locating the blower and blower motor. They may be separate units bolted together, or they may form a single unit, often with the motor bolted to the end so that it extends into the center of the squirrel cage wheel.In this episode of Repair and Replace, Vance shows how to replace the draft inducer blower in a gas furnace. The draft inducer fan pulls air into the burner....Find Fasco Furnace Motor Replacement Parts at RepairClinic.com. Repair for less! Fast, same day shipping. 365 day right part guaranteed return policy. En español. ... Fasco Furnace Blower Motor. Genuine OEM Part # D727 | RC Item # 2334143 # D727 RC Item # 2334143. Rating (5) 5 star rating. Reviews. Skill Level (3) We sell the real thing! Function and Components. The blower motor is typically located in the air handler or furnace. Its primary function is to drive the fan that circulates air through the furnace, over the heat exchanger, and then throughout your home via the ductwork. This circulation is essential not only for distributing heat but also for maintaining air quality ... How to replace a Carrier blower motor.Carrier Infinity fault code 41 diagnosis.Signs Your Furnace Blower Motor May Need Replacement. Identifying the early signs of a failing furnace blower motor can save you from cold nights and costly …1/4 HP - 115V Direct Drive Furnace Blower Motor Canada. $264.99. 1/3 HP - 115V Direct Drive Furnace Blower Motor Canada. $264.99. 1/2 HP - 115V Direct Drive Furnace Blower Motor Canada. Furnace Motors Canada distributes fasco exhaust inducer blower motors accross Canada. We ship to Ontario, Quebec, Manitoba, Saskatchawan, BC, Alberta, … The most common reasons for replacing the blower motor are when the furnace is loud or the blower motor does not run, but other more common problems have already been checked. All of the information in this blower motor replacement video is applicable to the following brands: Lennox Tools needed: 1/4 inch socket, 5/16 inch socket, adjustable ... Jan 8, 2024 · Learn what a furnace blower motor is, how long it lasts, and how to tell if it's bad. Find out how much it costs to replace a blower motor and why you should hire a pro to do it. Doing so may damage the furnace blower motor. ... Have available the Model No., Series Letter & Serial No. of your equipment to insure correct replacement part. Carrier Corporation • Syracuse, New York 13221. Manufacturer reserves the right to discontinue, or change at any time, ... Carrier Blower Motor Replacementwww.amazon.com/shop/miheatingguyMilwaukee 2131-20 M18 ROCKET Dual Power Tower Lighthttps://amzn.to/3pe2hYHMilwaukee M12 Surge... Replacement HVAC AC Motors. OEM Replacement AC Motors. OEM replacement AC motors extend equipment life by replacing old or damaged HVAC motors in ventilators, fans, and blowers. They match the equipment's existing motor from the original manufacturer to ensure consistent performance and correct installation. Aaon OEM Replacement.If your Ruud blower motor is not blowing the air properly or Making noise, it may be due to a bad blower motor. In this video, we'll show you how to change t...My Goodman Furnace blower was rumbling so I shopped for a replacement motor. There are so many choices and prices. You may have to google the customer # fi... Step By Step Instructions. Print Instructions. 1. Before you replace the blower motor in your furnace first turn off the power to the furnace. 2. Use a flat-head screwdriver to unthread the screws securing the upper access panel and remove the panel. 3. Next, unthread the screws to release the lower access panel. 4. 8 Apr 2015 ... How to replace and install 60L21 blower motor on a Lennox G40 LP furnace. We also show you how to remove and replace the blower wheel and ...Aftermarket blower motor for the Englander add-on furnace. NOTE: Does not include thermostat (AC-1339) or power cord. If you want the entire assembly (blower motor, thermostat and power cord), see AC-2835BA. Replacement For Part Numbers: BM-1376; 7090-2610; BM1376All my favorite HVAC tools: https://www.amazon.com/shop/thediyhvacguy?ref=ac_inf_tb_vhHowdy folks and welcome back to the channel. In this video we walk you ... About This Product. These motors install with all standard 48 in. Frame mounting brackets. They are a quiet operator and electrically reversible. There is an automatic thermal overload protector and they have class B insulation. The speed is 1075/3 and 60 Hz with low power consumption. The motor uses a 370-Volt Capacitor and has a standard 48 ...

Coleman Roof Jack Replacement Orifice Drill Size Chart Gas Orifices, ... Home › S1-7966-311P Coleman OEM Blower Motor, Blower, 1/6HP, 115Vac, Single Phase, 900 RPM, ... We are the industry experts on HVAC mobile home residential, commercial furnaces and air conditioners including Coleman, Duotherm, Nordyne, Intertherm and others.. Double acting baking powder

furnace blower motor replacement

Furnace/AC blower motor replacement or how to replace your furnace blower motor. We smelled a burnt plastic smell in the house and my wife mentioned that the... Furnace Blower Motor Cost. If your furnace is still under warranty, you may only have to pay around $150 for labor costs. But if your warranty has ended, Furnace Blower Motor Replacement Cost about $250 to $1000 without labor cost. You might spend up even more depends upon on the brand of your furnace. If you hire an HVAC technician, the ... Frequently bought together. This item: 60L21 - Lennox OEM Replacement Furnace Blower Motor 1/3 HP 115 Volt. $19500. +. Genteq GENTEQ - C305L / 27L570 GE Capacitor Oval 5 uf MFD 370 Volt 97F5705 (Replaces Old GE# Z97F5705, 97F95702, Z97F5702), 5uf 370 Vac (VAC), 5X370 Run Capacitor. $933.Learn when to replace or repair your furnace blower motor based on the age, condition, and cost of the unit. Find out the average costs, benefits, …22 Feb 2022 ... Unless you have a warranty for your unit, you can expect to pay anywhere from $1,000 to as much as $1,600 for a furnace blower motor replacement ...Nov 30, 2023 · The average cost to replace a broken furnace or air handler blower motor is around $290 when the part is under warranty and you pay just the labor cost. When the blower motor is not under warranty, the average cost is around $890 which includes parts and labor for a standard HVAC blower motor. The installed replacement cost should include a ... Steve at HvacPartsShop.com provides comprehensive guidance on the topic of universal replacement blower motors for HVAC applications. Watch Steve explain the...SUBURBAN RV FURNACE - Motor ReplacementModel NT 34 SPLink to purchase motor : https: ...Related: Furnace Replacement Cost and Blower Motor Cost. How Do You Know You Need a New Blower Motor? You know there is a problem when the furnace is not able to supply your home with warm air. Keep in mind that if your blower motor isn’t working because it’s overheating, merely replacing it won’t necessarily fix the problem. The real ...Get genuine Ruud factory OEM Blower Motors for your Ruud HVAC unit. All Ruud Blower Motors are brand new in the original factory packaging and are guaranteed to fit and function properly. We have fast FREE SHIPPING on all orders over $99 and ship all orders within 1 business day. Showing 1 - 12 of 647.A Dayton motor speed control is a part that’s typically used in HVAC systems, as noted by Zoro. These speed controls run on DC power, and you can also sometimes find them in indust...60L22 – Ducane OEM Replacement Furnace Blower Motor 1/2 HP 115 Volt Product Description & Features: This is a Brand New OEM Replacement Furnace Blower Motor Top Qualty OEM Replacement Part! 1/2 HP 115 Volt Brand: OEM Replm for Ducane Manufacturer: Ducane Estimated Price: $174.60 + More Info Including Updated …Furnace Blower Motor Replacement. Ask Question Asked 7 years ago. Modified 5 years, 3 months ago. Viewed 644 times 0 I have an old carrier Weathermaker DX 58DXA060-100GG, and the blower motor has no oilers. I assume it was a replacement for the original. My question is, because ...1 Sept 2023 ... Comments12 · Furnace/AC Blower Motor Replacement Step By Step · Carrier Ecm Blower Motor Troubleshooting · Fixed.. · Failed CARRIER X-13...This MOT19079 Blower Motor is a genuine replacement part for furnaces and is available now from Repair Clinic. ... Shop now and get same-day shipping on this MOT19079 Blower Motor. En español. 1-800-269-2609 24/7. Track Order. Log in or sign up. SHOP PARTS. ... Furnace Circulation Blower Fan Motor Replacement. View Solution. 02:28.by Lila Langford. How to Replace the Blower Motor in a Home Furnace and AC System. (with step-by-step photo guide) The following post …51-24144-01 - Weather King OEM Replacement Furnace Blower Motor 208-230 Volt . Brand: OEM Replm for Weather King. 1.0 1.0 out of 5 stars 1 rating | Search this page . Currently unavailable. We don't know when or if this item will be back in stock. Brand: OEM Replm for Weather King: Voltage: 230 Volts:9 Dec 2014 ... The problem is that when I was cleaning the shaft I tried to remove the rubber washer that act as a thrust spacer between the fan and the ....